Fire Alarm Systems, Fire Notice Systems, Fire Sensing Systems, Fire Detection Systems, System Sensor Turkey Distributor, Optical Smoke Detector, Gas Detector, Gas Detection Systems, Conventional Intelligent Addressable gas alarm control panels, Carbon Monoxide Detector, Ex-Proof Detector, Fire Alarm Call Point, Gas Sensing, Fire Alarm Panel, Intelligent Detector, Conventional Detector, Fire Extinguisher, Notifier, Siemens, Honeywell, Zeta, Firewize, Mircom, Bosch, Fike, Secutron, fire alarm system, fire alarm circuit, fire alarm system design, fire alarm systems, fire alarm control panel, fire alarm sound, fire alarm mp3, fire detection and alarm systems powerpoint, electricians guide to fire detection alarm systems, national certificate fire detection alarm systems, warehouse fire alarm systems, simplex fire alarm, fire alarm sounds, Facebook, Youtube, Google
Fire Alarm Systems

Conventional Fire Alarm Systems



- Special algorithms provide both a constant sensitivity level between service intervals and eliminate spurious alarms resulting from electrical noise
- Photo—thermal model provides outstanding protection
- Laser-based remote test unit — no need for ladders and towers
- Photoelectric, photo—thermal and thermal detectors
- Improved chamber design minimises the effects of dust contamination
- 8 to 30VDC operating voltage range provides compatibility with both fire and security systems
- -30° to +70°C operating temperature range
- Choice of bases (including a 12V relay version)
- Automatic drift compensation

Detectors       Sayfa Başı





1003 - Optical Smoke Detector

- Low profile design
- Low current draw
- Automatic drift compensation
- Operates on 12 and 24VDC Systems
- Remote alarm test feature
- Easy Maintenance
- Range of detector bases available
- Remote LED Option
- Extended warranty

Technical Document



1002 - Optical Smoke / Heat Detector

- Low profile design
- Low current draw
- Automatic drift compensation
- Operates on 12 and 24VDC Systems
- Remote alarm test feature
- Easy Maintenance
- Range of detector bases available
- Remote LED Option
- Extended warranty

Technical Document



1005 - ROR Temperature Detector

- Low profile design
- Low current draw
- Automatic drift compensation
- Operates on 12 and 24VDC Systems
- Remote alarm test feature
- Easy Maintenance
- Range of detector bases available
- Remote LED Option
- Extended warranty

Technical Document



1005T - Fixed Temperature Detector

- Low profile design
- Low current draw
- Automatic drift compensation
- Operates on 12 and 24VDC Systems
- Remote alarm test feature
- Easy Maintenance
- Range of detector bases available
- Remote LED Option
- Extended warranty

Technical Document



1004T - High Temperature Detector

- Low profile design
- Low current draw
- Automatic drift compensation
- Operates on 12 and 24VDC Systems
- Remote alarm test feature
- Easy Maintenance
- Range of detector bases available
- Remote LED Option
- Extended warranty

Technical Document



FCRI732 - Remote Indicator Led

- It is used in buildings that the separated in small places (hotel's rooms, hospitals) so as to be controlled easily

Technical Document

Call Points       Sayfa Başı





MCP3A - Call Point

- Sealed to IP67
- Unique 'Plug & Play' installation concept
- Total 'Flex-Ability' in the choice of operating element
- Anti-Tamper facility
- Enhanced aesthetics and compact design
- Fully approved to the latest standards
- CPD Approved

Technical Document



WCP3A - Call Point

- Sealed to IP67
- Unique 'Plug & Play' installation concept
- Total 'Flex-Ability' in the choice of operating element
- Anti-Tamper facility
- Enhanced aesthetics and compact design
- Fully approved to the latest standards
- CPD Approved

Technical Document



9300 + 9400 - Call Point

- Suitable for use as a manual activation device in smoke control management systems
- Wide range of configurations
- Also available as keyswitches & push buttons


Technical Document



Rocker Switch 9200 - Call Point

- Variety of rockerswitch devices available
- Suitable for Fire, Security & Other Specialist Applications
- Variety of colours and markings

Technical Document





Sounder/Strobe       Sayfa Başı





CWSO - Conventional Sounder

- Modern and aesthetic design
- Compatible with all systems
- High volume
- 32 different sound tones
- Volume adjustment
- Optional IP65 protection class
- Compatible for ceiling and wall mounting
- VDS, LPCB and CPR certificates

Technical Document



CWST - Conventional Strobe

- Modern and aesthetic design
- Compatible with all systems
- High volume
- 32 different sound tones
- Optional IP65 protection class
- Compatible for ceiling and wall mounting
- VDS, LPCB and CPR certificates


Technical Document



CWSS - Conventional Sounder Strobe

- Modern and aesthetic design
- Compatible with all systems
- High volume
- 32 different sound tones
- Volume adjustment
- Optional IP65 protection class
- Compatible for ceiling and wall mounting
- VDS, LPCB and CPR certificates

Technical Document



BS 595 - Electronic Alarm Bell

- High sound output
- Low current
- Simple installation



Technical Document



DBS - Convantional Detector Base Sounder

- 4-tone siren
- High sound output, low current consumption
- High reliability and stable performance
- Sound control
- Accessory for vertical use

Technical Document

Panels       Sayfa Başı



Yangın Alarm Paneli


FCE1002 - 2 Zone Conventional Fire Alarm Panel
FCE1004 - 4 Zone Conventional Fire Alarm Panel
FCE1006 - 6 Zone Conventional Fire Alarm Panel


- Mains voltage 220-240V AC / 50Hz
- 2/4/6 zones control capability
- Stabilized power supply 13,-8V/400mA
- 12V/7,2Ah (Pb) lead acid battery
- Autonomous duralion 36 hours (without use of 24V output)
- Up to 64 zone extensibility
- Two 24V fault monitored alarm circuits
- One Alarm relay, one Fault relay
- Programmable capability
- IP 20 cover protection
- Produced in accordance with EN54-2 and EN54-4
- Constructional materials: ABS
- Operation temperature: 0 to 60 ºC
- Humidity: Up to 95% relative humidity
- 1 year guarantee

Technical Document

Yangın Alarm Paneli


FCE1008 - 8 Zone Conventional Fire Alarm Panel
FCE1012 - 12 Zone Conventional Fire Alarm Panel
FCE1016 - 16 Zone Conventional Fire Alarm Panel


- Mains voltage 220-240V AC / 50Hz
- 8/12/16 zones control capability
- Stabilized power supply 13,-8V/400mA
- 12V/7,2Ah (Pb) lead acid battery
- Autonomous duralion 36 hours (without use of 24V output)
- Two 24V fault monitored alarm circuits
- One Alarm relay, one Fault relay
- Programmable capability
- IP 20 cover protection
- Produced in accordance with EN54-2 and EN54-4
- Constructional materials: ABS
- Operation temperature: 0 to 60 ºC
- Humidity: Up to 95% relative humidity
- 1 year guarantee

Technical Document

Yangın Alarm Paneli


FCE628EX - Cross Zone Fire Extinguishing Panel

- One fire extinguish output monitored for open and short circuit. The output can operate with actuators or electro valves
- Two cross zones for fire detectors
- One zone for a manual call point to start the extinguish procedure
- One zone for a manual call point to cancel the extinguish procedure
- Three modes of operation - The panel has two independent siren outputs
- One contact relay for fault status
- Two fully programable relay contacts
- Terminals to communicate with conventional fire detection panels

Technical Document

Power Supply       Sayfa Başı



Güç Kaynağı


ADV-12 Power Supply

- 12VDC power supply with battery backup
- 155W
- 88 - 264VAC input voltage range
- 47 - 63 Hz frequency
- Low power battery and battery polarity protection
- Düşük güç aküsü ve akü polarite koruması
- Free air convection cooling
- %100 full load operation test
- 2 year warranty

Technical Document

Güç Kaynağı


ADV-24 Power Supply

- 24VDC power supply with battery backup
- 155W
- 88 - 264VAC input voltage range
- 47 - 63 Hz frequency
- Low power battery and battery polarity protection
- Düşük güç aküsü ve akü polarite koruması
- Free air convection cooling
- %100 full load operation test
- 2 year warranty

Technical Document

Güç Kaynağı


ADV-55 Power Supply

- 55VDC power supply with battery backup
- 155W
- 88 - 264VAC input voltage range
- 47 - 63 Hz frequency
- Low power battery and battery polarity protection
- Düşük güç aküsü ve akü polarite koruması
- Free air convection cooling
- %100 full load operation test
- 2 year warranty

Technical Document


All Rights Reserved © ADEVA 2016